MONA MS database records for (LMST02030001)
Massbank ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
FiehnLib000226 | Leco Pegasus IV | GC-EI-TOF | - | - | - | positive | MS1 |
JP011651 | HITACHI M-2500 | EI-B | - | - | [M]+* | positive | MS1 |
CCMSLIB00000076968 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000085054 | qTof | - | - | - | [M+H]+ | positive | MS2 |
CCMSLIB00000578303 | Q-Exactive Plus | - | - | - | [M-H]- | negative | MS2 |
EQ320101 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 15 (nominal) | [M+H]+ | positive | MS2 |
EQ320102 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 30 (nominal) | [M+H]+ | positive | MS2 |
EQ320103 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 45 (nominal) | [M+H]+ | positive | MS2 |
EQ320104 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 60 (nominal) | [M+H]+ | positive | MS2 |
EQ320105 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 75 (nominal) | [M+H]+ | positive | MS2 |
EQ320106 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 90 (nominal) | [M+H]+ | positive | MS2 |
EQ320107 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 120 (nominal) | [M+H]+ | positive | MS2 |
EQ320108 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 150 (nominal) | [M+H]+ | positive | MS2 |
EQ320109 | Q Exactive Plus Orbitrap Therm... | LC-ESI-QFT | ESI | 180 (nominal) | [M+H]+ | positive | MS2 |
FiehnHILIC000276 | Thermo Q Exactive HF | LC-ESI-QFT | - | HCD (NCE 20-30-40%) | [M+H]+ | positive | MS2 |
MT000028 | LTQ XL, Thermo Finnigan | LC-ESI-IT | ESI | 40 | [M-H]- | negative | MS2 |
VF-NPL-LTQ000083 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2 |
VF-NPL-LTQ007163 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2 |
VF-NPL-QEHF000208 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000209 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000210 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF000211 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000212 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF000213 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013978 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013979 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013980 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M-H]- | negative | MS2 |
VF-NPL-QEHF013981 | Thermo Q Exactive HF | ESI-QFT | - | 35HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013982 | Thermo Q Exactive HF | ESI-QFT | - | 45HCD | [M+H]+ | positive | MS2 |
VF-NPL-QEHF013983 | Thermo Q Exactive HF | ESI-QFT | - | 65HCD | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001961 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001962 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001963 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M-H]- | negative | MS2 |
VF-NPL-QTOF001964 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID10 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001965 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID20 | [M+H]+ | positive | MS2 |
VF-NPL-QTOF001966 | Agilent 6530 Q-TOF | ESI-QTOF | - | CID40 | [M+H]+ | positive | MS2 |
VF-NPL-LTQ000084 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M-H | negative | MS2-MS4 Composite |
VF-NPL-LTQ007164 | Thermo Finnigan LTQ | Linear Ion Trap | - | 35 | M+H | positive | MS2-MS4 Composite |
HMDB0014879_c_ms_2277 | Thermo Finnigan LTQ | GC-MS | - | - | - | - | - |