MassBank.eu ID
|
Instrument
|
Inst. type
|
MS type
|
Collision energy
|
Ion type
|
Ion mode
|
MS level
|
MSBNK-Kazusa-KZ000066
|
Pegasus III TOF-MS system, Leco; GC 6890, Agilent Technologies
|
GC-EI-TOF
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Keio_Univ-KO001605
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
10 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Keio_Univ-KO001606
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
20 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Keio_Univ-KO001607
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
30 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Keio_Univ-KO001608
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
40 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Keio_Univ-KO001609
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
50 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Keio_Univ-KO003695
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
10 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO003696
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
20 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO003697
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
30 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO003698
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
40 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO003699
|
API3000, Applied Biosystems
|
LC-ESI-QQ
|
-
|
50 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO009182
|
LC/MSD Trap XCT, Agilent Technologies
|
LC-ESI-IT
|
-
|
0.7
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Keio_Univ-KO009183
|
LC/MSD Trap XCT, Agilent Technologies
|
LC-ESI-IT
|
-
|
0.60/0.50
|
[M+H]+
|
POSITIVE
|
MS3
|
MSBNK-Keio_Univ-KO009184
|
LC/MSD Trap XCT, Agilent Technologies
|
LC-ESI-IT
|
-
|
0.70/0.50
|
[M+H]+
|
POSITIVE
|
MS3
|
MSBNK-Keio_Univ-KO009185
|
LC/MSD Trap XCT, Agilent Technologies
|
LC-ESI-IT
|
-
|
0.60/0.50/0.40
|
[M+H]+
|
POSITIVE
|
MS4
|
MSBNK-Keio_Univ-KO009186
|
LC/MSD Trap XCT, Agilent Technologies
|
LC-ESI-IT
|
-
|
0.60/0.50/0.40
|
[M+H]+
|
POSITIVE
|
MS4
|
MSBNK-LCSB-LU087001
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
15
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087002
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
30
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087003
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
45
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087004
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
60
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087005
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
75
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087006
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
90
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-LCSB-LU087051
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
15
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-LCSB-LU087052
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
30
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-LCSB-LU087053
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
45
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-LCSB-LU087054
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
60
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-LCSB-LU087055
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
75
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-LCSB-LU087056
|
Q Exactive Orbitrap (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
90
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Metabolon-MT000131
|
LTQ XL, Thermo Finnigan
|
LC-ESI-IT
|
-
|
40
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Osaka_Univ-OUF00414
|
Pegasus III TOF-MS system, Leco; GC 6890, Agilent Technologies
|
GC-EI-TOF
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-RIKEN-PR010017
|
Pegasus III TOF-MS system, Leco; GC 6890, Agilent Technologies
|
GC-EI-TOF
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-RIKEN-PR010018
|
Pegasus III TOF-MS system, Leco; GC 6890, Agilent Technologies
|
GC-EI-TOF
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-RIKEN-PR100040
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
Ramp 5-60 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN-PR100041
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
30 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN-PR100295
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
Ramp 5-60 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN-PR100400
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
Ramp 5-60 V
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN-PR100728
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
Ramp 5-60 V
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN-PR100858
|
UPLC Q-Tof Premier, Waters
|
LC-ESI-QTOF
|
-
|
Ramp 5-60 V
|
[M-H]-
|
NEGATIVE
|
MS2
|