MassBank.eu database records for Lauroyl-EA (LMFA08040041)
BackMassBank.eu ID | Instrument | Inst. type | MS type | Collision energy | Ion type | Ion mode | MS level |
---|---|---|---|---|---|---|---|
MSBNK-UFZ-UP000001 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 10 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000003 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 20 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000005 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 30 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000028 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 15 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000030 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 25 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000032 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 35 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000055 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 40 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000057 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 50 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000059 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 60 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000082 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 45 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000084 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 55 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000086 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 65 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000108 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 70 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000110 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 80 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000112 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 90 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000132 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 75 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000134 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 85 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000136 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 95 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000155 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 100 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000157 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 110 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000159 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 120 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000176 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 105 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000178 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 115 % (nominal) | [M+H]+ | POSITIVE | MS2 |
MSBNK-UFZ-UP000180 | LTQ Orbitrap XL Thermo Scientific | LC-ESI-ITFT | - | 125 % (nominal) | [M+H]+ | POSITIVE | MS2 |