MassBank.eu ID
|
Instrument
|
Inst. type
|
MS type
|
Collision energy
|
Ion type
|
Ion mode
|
MS level
|
MSBNK-ACES_SU-AS000110
|
QExactive Orbitrap HF-X (Thermo Scientific)
|
LC-APCI-QFT
|
-
|
Ramp 20%-70% (nominal)
|
-
|
POSITIVE
|
MS2
|
MSBNK-ACES_SU-AS000181
|
QExactive Orbitrap HF-X (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
Ramp 20%-70% (nominal)
|
-
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105401
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
10 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105402
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
20 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105403
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
30 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105404
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
40 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105405
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
50 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105406
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
Ramp 30.5-45.7 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105407
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
10 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105408
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
20 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105409
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
30 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105410
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
40 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105411
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
50 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108075
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
60
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108076
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108077
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
100
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108078
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
30
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108079
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
20
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108080
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108081
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
80
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108082
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
120
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108083
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
140
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108084
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
130
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108085
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
50
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108086
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
70
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108087
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
90
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108088
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
110
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108089
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
150
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108090
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
10
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018901
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
35 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018902
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
15 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018903
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
30 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018904
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
45 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018905
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
60 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018906
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
75 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018907
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
90 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018908
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
15 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018909
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
30 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018910
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
45 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018911
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
60 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018912
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
75 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018913
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
90 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA018914
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
35 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-IPB_Halle-PB005801
|
micrOTOF-Q
|
LC-ESI-QTOF
|
-
|
10 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-IPB_Halle-PB005802
|
micrOTOF-Q
|
LC-ESI-QTOF
|
-
|
15 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-IPB_Halle-PB005803
|
micrOTOF-Q
|
LC-ESI-QTOF
|
-
|
20 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-IPB_Halle-PB005804
|
micrOTOF-Q
|
LC-ESI-QTOF
|
-
|
30 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-MPI_for_Chemical_Ecology-CE000001
|
LTQ Orbitrap XL, Thermo Scientfic; HP-1100 HPLC, Agilent
|
LC-ESI-ITFT
|
-
|
35eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-MPI_for_Chemical_Ecology-CE000002
|
LTQ Orbitrap XL, Thermo Scientfic; HP-1100 HPLC, Agilent
|
LC-ESI-ITFT
|
-
|
45eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-MPI_for_Chemical_Ecology-CE000003
|
LTQ Orbitrap XL, Thermo Scientfic; HP-1100 HPLC, Agilent
|
LC-ESI-ITFT
|
-
|
55eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-MPI_for_Chemical_Ecology-CE000004
|
LTQ Orbitrap XL, Thermo Scientfic; HP-1100 HPLC, Agilent
|
LC-ESI-ITFT
|
-
|
70eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-MPI_for_Chemical_Ecology-CE000005
|
LTQ Orbitrap XL, Thermo Scientfic; HP-1100 HPLC, Agilent
|
LC-ESI-ITFT
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-RIKEN_NPDepo-CB000347
|
ABSciex API3200 LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS
|
MSBNK-RIKEN_NPDepo-NGA01645
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA01646
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA01647
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA01648
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04305
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04306
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04307
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04308
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-UFZ-WANA002403B085PH
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
20 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-UFZ-WANA0024237762PH
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
80 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-UFZ-WANA002425AF82PH
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
90 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Washington_State_Univ-BML81200
|
Agilent 1200 RRLC; Agilent 6520 QTOF
|
LC-ESI-QTOF
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Washington_State_Univ-BML81201
|
Agilent 1200 RRLC; Agilent 6520 QTOF
|
LC-ESI-QTOF
|
-
|
-
|
-
|
NEGATIVE
|
MS
|
MSBNK-Waters-WA002281
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002282
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002283
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002284
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002285
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002286
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
POSITIVE
|
MS
|
MSBNK-Waters-WA002287
|
ZQ, Waters
|
LC-ESI-Q
|
-
|
-
|
-
|
NEGATIVE
|
MS
|