MassBank.eu ID
|
Instrument
|
Inst. type
|
MS type
|
Collision energy
|
Ion type
|
Ion mode
|
MS level
|
MSBNK-ACES_SU-AS000096
|
QExactive Orbitrap HF-X (Thermo Scientific)
|
LC-APCI-QFT
|
-
|
Ramp 20%-70% (nominal)
|
-
|
POSITIVE
|
MS2
|
MSBNK-ACES_SU-AS000166
|
QExactive Orbitrap HF-X (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
Ramp 20%-70% (nominal)
|
-
|
POSITIVE
|
MS2
|
MSBNK-ACES_SU-AS000237
|
QExactive Orbitrap HF-X (Thermo Scientific)
|
LC-ESI-QFT
|
-
|
Ramp 20%-70% (nominal)
|
-
|
NEGATIVE
|
MS2
|
MSBNK-Athens_Univ-AU105301
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
Ramp 30.8-46.2 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105302
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
20 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105303
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
30 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105304
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
40 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105305
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
50 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105306
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
10 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105307
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
10 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105308
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
20 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105309
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
30 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105310
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
40 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Athens_Univ-AU105311
|
Bruker maXis Impact
|
LC-ESI-QTOF
|
-
|
50 eV
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311092935
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-BAFG-CSL2311092937
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
30
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-BAFG-CSL2311092938
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
10
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-BAFG-CSL2311092939
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
20
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-BAFG-CSL2311108132
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
150
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108133
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
110
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108134
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108135
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
120
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108136
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
60
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108137
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
10
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108138
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
30
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108139
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
130
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108140
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
100
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108141
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
80
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108142
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
70
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108143
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108144
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
50
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108145
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
90
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108146
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
140
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108147
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
20
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-BAFG-CSL2311108252
|
TripleTOF 5600 SCIEX
|
LC-ESI-QTOF
|
-
|
40
|
[M-H]-
|
NEGATIVE
|
MS2
|
MSBNK-Eawag-EA019101
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
35 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019102
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
15 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019103
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
30 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019104
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
45 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019105
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
60 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019106
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
75 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019107
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
90 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019108
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
15 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019109
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
30 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019110
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
45 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019111
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
60 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019112
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
75 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019113
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
90 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-Eawag-EA019114
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
35 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-CB000348
|
ABSciex API3200 LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS
|
MSBNK-RIKEN_NPDepo-NGA02557
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA02558
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA02559
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA02560
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04693
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04694
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04695
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-RIKEN_NPDepo-NGA04696
|
Agilent 6410 Triple Quadrupole LC/MS system
|
LC-ESI-QQQ
|
-
|
-
|
[M+HCOO]-
|
NEGATIVE
|
MS2
|
MSBNK-UFZ-WANA017103B085PH
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
20 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|
MSBNK-UFZ-WANA017105070APH
|
LTQ Orbitrap XL Thermo Scientific
|
LC-ESI-ITFT
|
-
|
30 % (nominal)
|
[M+H]+
|
POSITIVE
|
MS2
|